PVC Membrane Application Guide

Specifying a PVC waterproof membrane is usually a question of where the sheet will sit: an exposed roof, a backfilled basement, a tunnel lining or a water-retaining structure. This guide routes each project type to the same hot-air welded sheet — supplied in 1.2, 1.5 and 2.0 mm — and shows which values actually decide the specification on site. For exposed single-ply work, the PVC roofing membrane section below covers seams, thickness and detailing.

  • EN 13956
  • CE & CPR
  • ISO 9001
1 (63).png

PVC Roofing Membrane for Exposed Single-Ply Roofs

An exposed roof carries the full weather load, so the sheet has to hold its properties through UV, ozone and temperature swings. The product page lists weather resistance, UV and ozone resistance, and extreme-temperature adaptability for exactly this kind of duty.

The joints decide whether the roof performs. This sheet is hot-air weldable and forms a seamless joint, so the finished roof behaves as one continuous waterproof layer rather than a set of overlapped laps. Thickness of 1.2, 1.5 or 2.0 mm lets a specifier match the sheet to exposure and traffic, and custom thickness is available.

Buyer decisionConfirm the thickness your specification calls for, and confirm that hot-air welding equipment and a trained operator will be on site before the deck is closed up.

PVC waterproof membrane being laid for an exposed single-ply roof
One welded sheet across the field, with the same hot-air method carried up to upstands and penetrations.
  • ≥1200 N/50mmTensile strength
  • ≥200%Elongation at break
  • −25 °CLow-temperature flexibility, no cracking
  • 1.2–2.0 mmThickness, custom available
≥200%Elongation at break
−25 °CFlexibility with no cracking
≤±0.5%Dimensional stability

An underground lining is rarely flat. The sheet has to follow an uneven substrate and absorb slight structural deformation without opening at a seam — which is where elongation and low-temperature behaviour stop being catalogue numbers and start being the reason a lining stays dry. Hot-air welded, seamless joints then turn individual sheets into one overall waterproof structure across the whole profile.

Buyer decisionAgree the joint layout and the tolerance the substrate must meet before welding starts, so any variation is absorbed by the sheet rather than concentrated at a seam.

Reservoirs, Sewage Treatment Structures and Water-Retaining Works

Reservoirs and sewage treatment structures are named on the product page alongside roofs, basements and tunnels. On these jobs the deciding properties are tight sealing and a joint that stays closed, because the membrane is the barrier between stored water and the structure behind it.

The sheet is described with excellent flexibility, outstanding heat welding performance and tight sealing capability, and it is rated water impermeable at 0.3 MPa over 24 hours. Standardized production processes support the stable quality, adaptability and cost-effectiveness the page attributes to this material.

Buyer decisionFix the jointing sequence with the applicator first, then confirm how the membrane terminates against concrete jointing components at the base slab and walls.

MaterialPVC
Joint methodHot-air weldable, seamless joint
Impermeability0.3 MPa / 24 h, no leakage
ComplianceEN 13956, CE & CPR, ISO 9001

What the four scenarios have in common

Every module above lands on the same sheet specification. The difference between projects is which value leads the conversation — thickness on a roof, impermeability below grade, elongation underground, sealing in a tank.

Full Specification of the PVC Waterproof Membrane

Every figure below is taken from the product page and applies to all four application modules on this guide.

Product nameWaterproof membrane
MaterialPVC
Thickness1.2 / 1.5 / 2.0 mm; custom available
Tensile strength≥1200 N/50mm
Tear resistance≥250 N
Elongation at break≥200%
Low-temperature flexibility−25 °C, no cracking
Water impermeabilityNo leakage under 0.3 MPa, 24 h
Dimensional stability≤±0.5%
Standard complianceEN 13956, CE, ISO 9001 (CE & CPR requirements)
WeldabilityHot-air weldable, seamless joint
Typical applicationsBuilding roofs, basements, tunnels, reservoirs, sewage treatment structures

Scenario-to-Specification Decision Table

Read across each card to see which value governs the choice and what still has to be confirmed before the order is placed.

Exposed roof

Governing valueThickness within 1.2–2.0 mm, weather / UV / ozone resistance, hot-air weldable seamless joints.
Confirm before orderingThe specified thickness, welding equipment availability, and the detail carried up to upstands.

Backfilled basement

Governing valueWater impermeability at 0.3 MPa / 24 h, tensile strength ≥1200 N/50mm, dimensional stability ≤±0.5%.
Confirm before orderingProtection-layer sequencing ahead of backfill and the junction with the waterstop at construction joints.

Tunnel lining

Governing valueElongation at break ≥200%, low-temperature flexibility at −25 °C, seamless welded structure.
Confirm before orderingSubstrate regularity tolerance and the joint layout across the profile.

Reservoir or sewage works

Governing valueTight sealing, excellent flexibility, 0.3 MPa / 24 h impermeability, EN 13956 conformity.
Confirm before orderingJointing sequence and how the membrane terminates at base slab and wall joints.

Request a Quote, a Sample or the Catalog

Tell us the project type, the thickness you need — 1.2, 1.5 or 2.0 mm, or a custom thickness — and the quantity. Quotes, samples and the product catalog are all available on request.

Speak to the membrane team

Related Reading

Three notes to help clarify product requirements before contacting the supplier.

PVC Roofing Membrane Performance on Exposed Commercial Roof

A guide to PVC membrane performance on exposed commercial roofs.

Read article

PVC Waterproof Membrane in Basement Tanking Under Groundwater

A look at PVC membrane waterproofing for basements exposed to groundwater.

Read article

What Does EN 13956 Cover for PVC Roofing Membrane

An overview of what EN 13956 covers for PVC roofing membranes.

Read article

Frequently Asked Questions

what thicknesses are available for the pvc waterproof membrane?

the membrane is supplied in 1.2 mm, 1.5 mm and 2.0 mm thicknesses, with custom thickness available on request.

which applications is this pvc membrane designed for?

it is intended for building roofs, basements, tunnels, reservoirs and sewage treatment structures, where a hot-air welded pvc sheet is used to resist water seepage.

how are the pvc membrane seams joined?

the sheet is hot-air weldable and forms a seamless joint, using its heat welding performance to create tight sealing and an overall continuous waterproof structure.

what are the key mechanical and waterproofing values?

tensile strength is ≥1200 n/50mm, tear resistance is ≥250 n, elongation at break is ≥200%, low-temperature flexibility is −25 °c with no cracking, and water impermeability is no leakage under 0.3 mpa for 24 hours. dimensional stability is ≤±0.5%.

which standards and certifications does the membrane meet?

the product is stated to comply with en 13956, meet ce and cpr requirements, and be manufactured under an iso 9001 quality system.

can i request a sample, a quote or a custom thickness?

yes. custom thickness is available, and a free sample, a quote and the product catalog can be requested by email at jimmy@arisonsltd.com or by phone at +86 139 1458 5556.